1. Input Voltage Range: 90Vac to 264Vac, single phase.
2. Input AC Current: 2.3A max @ 100-240Vac input & Full load.
3. Inrush Current (Cold Start): Not exceeding 120A at 240Vac input and Max load at 25℃.
4. Average Efficiency: More than 86.0% at 115Vac and 230Vac input (tested at 25%, 50%, 75%, and 100% load).
5. Energy Consumption: Input power loss is less than 0.21W at no-load condition with 115Vac or 230Vac input.
6. Turn-on Delay Time: 3S max @ 100Vac to 240Vac input & Full load.
7. Hold-up Time: 5mS min @ Full load & 230Vac/50Hz input turn off.
8. Capacitance Load: Adapter turns on normally under 100~240Vac input with a 470uF capacitance load.
9. Output Overshoot / Undershoot: 10% max when power is turned on or off.
10. Output Load Transient Response: Max 10% of nominal output voltage; load fluctuation: 20% to 80%, R/S: 0.5A/uS, frequency: 100Hz.
11. Over Current Protection: 4.5-8A current limit. Output enters hiccup mode and self-recovers once fault is removed.
12. Short Circuit Protection: Input power decreases during short circuit; no damage to power supply, with automatic recovery.
13. Over Voltage Protection: Built-in protection operates when output exceeds voltage limits.
14. Operating Environment: Temperature 0°C to +40°C; Relative Humidity 10%RH to 90%RH.
15. Storage Environment: Temperature -20°C to +80°C; Humidity 5%RH to 95%RH non-condensing.
16. Vibration Test: 10 to 300Hz sweep at constant 1.0G acceleration for 1 hour along X, Y, Z axes.
17. Waterproof Standard: IP67 reference. Tested with 12.5mm nozzle water flow at 100 L/min for 3 min, and vacuum suction pressure of 3Kg/F for 3S.
18. Reliability & MTBF: Minimum 4 hours burn-in at 40°C ± 5°C under 80% load. MTBF ≥ 50,000 hours at 25°C full load.
19. Dielectric Strength (Hi-pot): Primary to Secondary: 4242VDC or 3000VAC / 5mA Max / 60 seconds.
20. Leakage Current: 0.25mA max at 264Vac / 50Hz.
21. Insulation Resistance: 50MΩ minimum at primary to secondary with 500Vdc test voltage.